Breast


Background

Breast cancer is a malignant tumour that originates in the cells of the breast. It is one of the most commonly diagnosed types of cancer among women. The lifetime risk of developing breast cancer in industrialized countries is at a level of one in seven women. Early detection and diagnosis are of key importance for effective treatment of breast cancer. However, current diagnostic methods are insufficient to detect all breast cancers in time. This is mainly shown by the condition that we fail to prevent metastatic spread and to adequately monitor treatment. Consequently, new methods are required to improve early cancer detection in a screening setting and after detection to guide and monitor treatment. Ultrasound imaging might be an excellent choice since it has low costs, is real-time en does not use hazardous radiation. However, ultrasound imaging lacks adequate specificity and requires well-educated radiologist to interpret breast ultrasound images. Therefore, our research goal is to improve the detection, diagnosis and monitoring of breast cancer using ultrasound imaging and related methods. Furthermore, we aim to develop low-cost ultrasound and CAD systems to facilitate breast cancer detection for health care workers in developing countries.


Methods


Ultrafast ultrasound imaging

The automated breast volume scanner (ABVS) is capable of recording ultrasound images of the entire breast that can be evaluated afterwards by radiologist to detect suspicious lesions. One of the limitations of this scanner is the long scan times up to 90 seconds to record one volume. Those long scan times introduce breathing artefacts and, consequently, possible lesions can be missed and misclassified. We are developing ultrafast ultrasound imaging techniques (LINK: quantitative) to decrease scan times to a few seconds without compromising and even increasing the image quality (contrast and resolutions).


3D Breast ultrasound elastography

In automated breast volume scanners (ABVS), and ultrasound imaging in general, it is often hard to discriminate between benign lesions and breast cancers. Consequently, the specificity of ultrasound imaging is lacking despite its high sensitivity. Ultrasound elastography, more specific Strain Imaging might be an excellent method to discriminate between lesion types. Breast cancers are often stiff and grown into its surrounding tissue whereas benign lesions are often soft and loosely bonded to surrounding breast tissue. In our research projects, we developed 3D strain imaging for ABVS to obtain strain and shear strain as measure for lesion stiffness and bonding, respectively. This method was validated in simulations, phantoms and in-vivo.


3D Doppler and perfusion imaging

Another way to improve the specificity of ultrasound imaging is to detect the blood flow in and around suspected lesions. Breast cancers often have higher vascularization due to angiogenesis compared to benign lesions. With ultrasound Doppler techniques and perfusion imaging blood velocities and flows. We are developing 3D Doppler for the automated breast volume scanner to detect low blood flows around lesions. Furthermore, we are investigating ultrasound perfusion imaging using contrast agents (microbubbles) to visualize the vascularisation of lesions and to determine related parameters to classify lesions like wash-in/our curves.


Quantitative ultrasound

Quantitative ultrasound is another option to improve the specificity of ultrasound images. In 3D ultrasound, accurate discrimination of small solid masses is difficult, resulting in a high frequency of biopsies for benign lesions.
Therefore we explored and incorporated the Computer Aided UltraSound (CAUS) protocol (developed for hepatic steatosis classification) to enable quantitative and relative expression of the echolevels using a reference phantom method. We adapted the software such that ik could handle 3D ultrasound (US) volumes originating from the Siemens ABVS system, and made it a generic method by expressing echolevels relative to a reference phantom. From the 3DUS images the relative echolevel statistics as well as the "residual attenuation coefficient" were estimated after manual deliniation of the suspected lesions in 3D. Furthermore we incorporated echo level features like the peritumoural surrounding (PER) and posterior-tumoural phenomena (POS) echo level.

Hybrid tomosynthesis-ultrasound system

After a suspicious lesion is detected by tomosynthesis, it is often further evaluated using ultrasound imaging to determine whether it concerns a breast cancer or a benign lesion. Consequently, women have to be recalled after a tomosynthesis image is made for an ultrasound exam. To simplify this procedure, we aim to develop a hybrid tomosynthesis-ultrasound system in which tomosynthesis and ultrasound images are obtained almost simultaneously. The advantage is that the radiologist can simultaneously evaluate images of both devices. In this way, an unnecessary recall can be prevented and the procedure time reduced. Furthermore, some lesions are hardly visible on tomosynthesis but can be seen on ultrasound or vice versa. In our research, we are developing ultrasound scan acquisitions to reduce the scan time and to increase the image quality especially at lower depths (up to 10 cm). We are also investigating the addition of ultrasound elastography and Doppler imaging to further improve the performance of this hybrid system.


Breast Volumetric Imaging for Biopsy Navigation

After imaging with mammography, ultrasound (US) imaging of a lesion with subsequent breast biopsy is common clinical practice to determine whether the lesion is malignant or benign. Among available breast biopsy techniques, ultrasound-guided core needle biopsy (CNB) is preferable. However, this technique cannot be applied if the lesion is US occult (not detectable in the echogram), and the radiologist has to perform MRI-guided biopsy that is time-consuming and cost-ineffective. The objective of the MRI-Ultrasound Robotic Assisted Biopsy (MURAB) project is to facilitate US-guided biopsy even for US occult lesions and simplify the work of radiologists. The procedure comprises 5 major steps: MRI imaging, ultrasound volumetric imaging, MRI-US image fusion & lesion localization, needle navigation, and biopsy. The MURAB project involves 5 partners (Radboudumc, University of Twente, University of Verona, Siemens Healthineers, KUKA robotics, and Medical University of Vienna), who work in collaboration on the MURAB clinical setup. In the MUSIC group, we focus on the development and validation of methods for breast automated volumetric imaging for US -MRI image fusion. We are working on complimentary approaches: breast 3D-US imaging with an automated cone-base scanner and breast 3D-US imaging with free-hand volumetric ultrasound.


Results


Ultrasound image quality

In our studies, we compared the image quality between ultrafast ultrasound (plane-wave) imaging and the currently used conventional focused acquisitions in the ABVS system. Our results suggest that ultrafast imaging will enable breath-hold ABVS examinations, eliminating breathing artifacts while otherwise preserving similar image quality (contrast and resolution). Therefore, 11 steering angles were used in ultrafast imaging resulting in an 18 times increased frame rate. We showed that the frame rate and ABVS transducer moving speed did not significantly affect the image quality (Figure 1). Currently, we are investigating several reconstruction and filtering methods to improve the image quality in ultrafast ultrasound imaging Quantitative Ultrasound.

MUSIC Breast USImagQuality.png

Figure 1: Coronal (up), transverse (down left) and sagittal (down right) views of a cyst extracted from a 3-D breast phantom volume acquired by moving the transducer by: a) 10 mm/s, b) 20 mm/s and c) 50 mm/s. In the first image CNR measurement positions are indicated (blue: cyst, red: background). In b) and c), only the area around the cyst is shown (Hollander et al., 2016).

3D Breast ultrasound elastography

We developed 3D breast ultrasound elastography for the ABVS system. This technique was validated in simulations, phantoms and in a patient study. Our results show that stiff breast lesions can be discriminated from surrounding breast tissue (Figure 2) and that breast cancers showed an increased strain ratio compared to benign lesions. In a simulation and phantom study, we showed that lesion bonding (shear-strain) can be measured by 3D ultrasound elastography: benign, loosely bonded lesions) show high shear-strain values around the lesion while breast cancers show low values.

MUSIC Breast Elastography.png

Figure 2: Strain ratios superimposed on top of B-mode images of an IDC in the coronal (green), transverse (blue) and sagittal plane (yellow). The plane positions are also indicated in the 3D B-mode volume (right-top corner). The IDC is indicated by the purple arrows and was detected medial of the nipple in the right breast in this example. The strain ratios varied between 0 (blue; stiff), 3 (green, intermediate) and 6 (red, soft) (PhD Thesis Hendriks).

3D Doppler and perfusion imaging

3D ultrafast ultrasound data was obtained from a breast with a malignant lesion using a translating 5 Mhz ultrasound probe which ultrafastly transmitted plane wave ultrasound. The 3D power Doppler volume data is visualized below. Besides the volumetric representation, 2 intersecting planes are presented as slices. It can be observed that few clouds of Doppler signals present at both the center and margin of the lesion. More details on the theory behind the implemented method and simulation results can be found in (Chen, 2021). The presented in vivo images and and additional results have been published in (Chen, 2022)

3D perfusion

Figure 3: In-vivo experiment on malignant breast lesion. Both Doppler volume (left panel) and two crossing slices (middle and right panel) are presented."

Quantitative ultrasound

We applied 3D quantitative breast ultrasound (3DQBUS) to 3D US studies of 112 biopsied solid breast lesions with a size smaller then 1 cm. The resulting features were used for classification of the lesion by a logistic regression analysis. The classification accuracy was evaluated by leave-one-out cross-validation. The area under the ROC curve was 0.86 for both readers. 3DQBUS is a promising technique to classify suspicious breast lesions as benign, potentially preventing unnecessary biopsies (Meel et al. 2017).

Breast Volumetric Imaging for Biopsy Navigation

We developed different scanning approaches. Results show volumetric images of a custom-developed phantom, scanned with an ultrasound transducer mounted on a robotic arm (top) and with a transducer integrated in the wall of an automatically rotating cone-shaped container (bottom). More results of the cone-based volumetric ultrasound breast imaging scanner have been published in (Nikolaev, 2021)

Breast 3D quant.png
Figure 4: Volumetric imaging of the breast volumetric phantom with the robotic arm (top) and automated cone-shaped container (bottom). From left to right: the imaging setup(a, d), rendered volumetric data (b, e), and coronal cross-sectional image (c, f).

Subsequently, we co-registered in-vivo MRI and 3D US data in a volunteer with a benign lesion (fibroadenoma) and a cyst. The same cross-sections were taken for clear observation of the fibroadenoma and the cyst. Dark areas in US images represent fat, while bright areas represent glandular tissue. Both fibroadenoma and cyst are visible as dark spots and pointed out with arrows. In the MRI images (T2 sequence Dixon protocol, fat), glandular tissue is represented as a shaded area while bright represents fat. Both lesions are visible and characterized by dark spots. The skin layer is occult in the utilized MRI image.

Breast 3Drecon.jpg
Figure 5: MRI-3D US image fusion of a breast. a) Rendered MRI data with indicated cross-sectional transversal plain. b) Cross-sectional US image. b) Cross-sectional MRI image. c) MRI data overlayed 3D US data.

Funding

  • X-US: Combined ABVS and Tomosynthesis scanning (supported by Siemens Healthineers, active)
  • 3D FUSION BREAST: 3D Functional UltraSound Imaging Of Nodules in BREAST (supported by Dutch Technology Foundation and Siemens, finished)
  • MURAB: MRI and Ultrasound Robotic Assisted Biopsy (supported by Horizon 2020 (688188), Siemens, and KUKA, active). MURABproject.eu

Key publications

  • A. Nikolaev, L. De Jong, G. Weijers, V. Groenhuis, R. Mann, F. Siepel, B. Maris, S. Stramigioli, H. Hansen and C. De Korte. "Quantitative Evaluation of an Automated Cone-based Breast Ultrasound Scanner for MRI - 3D US Image Fusion.", 2021. Abstract/PDF DOI PMID

  • C. Chen, H. Hansen, G. Hendriks, J. Menssen, J. Lu and C. de Korte. "Point Spread Function Formation in Plane-Wave Imaging: A Theoretical Approximation in Fourier Migration.", 2020. Abstract/PDF DOI PMID

  • G. Hendriks, H. Hansen, C. De Korte and C. Chen. "Optimization of transmission and reconstruction parameters in angular displacement compounding using plane wave ultrasound.", 2020. Abstract/PDF DOI PMID

  • C. Chen, G. Hendriks, R. van Sloun, H. Hansen and C. de Korte. "Improved Plane-Wave Ultrasound Beamforming by Incorporating Angular Weighting and Coherent Compounding in Fourier Domain.", 2018. Abstract/PDF DOI PMID

  • G. Hendriks, C. Chen, H. Hansen and C. de Korte. "Quasi-static elastography and ultrasound plane-wave imaging: The effect of beam-forming strategies on the accuracy of displacement estimations", 2018. PDF

  • G. Hendriks, C. Chen, H. Hansen and C. de Korte. "3-D Single Breath-Hold Shear Strain Estimation for Improved Breast Lesion Detection and Classification in Automated Volumetric Ultrasound Scanners.", 2018. Abstract/PDF DOI PMID

  • A. van den Abeelen, G. Weijers, J. van Zelst, J. Thijssen, R. Mann and C. de Korte. "3D quantitative breast ultrasound analysis for differentiating fibroadenomas and carcinomas smaller than 1cm", 2017. Abstract/PDF DOI PMID

  • B. Holländer, G. Hendriks, R. Mann, H. Hansen and C. de Korte. "Plane-Wave Compounding in Automated Breast Volume Scanning: A Phantom-Based Study.", 2016. Abstract/PDF DOI PMID

  • G. Hendriks, B. Holländer, J. Menssen, A. Milkowski, H. Hansen and C. de Korte. "Automated 3D ultrasound elastography of the breast: a phantom validation study.", 2016. Abstract/PDF DOI PMID